6. SysEx Messages
35
Data Bytes: 3
Data Bytes per Encoder : Not Applicable
Message for Default Settings:
< 240, 0, 1, 106, 01, 05, 126, 05, 01, 247 >
06 : FSR Settings
This message changes all settings for all pads.
1st Data Byte Received: CC Retrigger On (Force Sensitive Pads 1-7)
2nd Data Byte Received: CC Retrigger On (Force Sensitive Pad 8)
3rd Data Byte Received: Note On Pressure Threshold (Low)
4th Data Byte Received: Note On Pressure Threshold (High)
5th Data Byte Received: Note O Pressure Threshold (Low)
6th Data Byte Received: Note O Pressure Threshold (High)
7th Data Byte Received: CC Resend Rate
8th Data Byte Received: Force Sensitive Pad Sensitivity
Total Bytes: 10
Data Bytes: 3
Data Bytes per Pad: Not Applicable
Message for Default Settings:
< 240, 00, 01, 106, 01, 06, 127, 127, 15, 00, 07, 00, 09, 5, 247 >